  万兆SFP+模块,可以兼容多个品牌交换机
 
      
| Parameters | Symbol | Min. | Max. | 
| Storage Temperature (°C) | Tst | -40 | +85 | 
| Supply Voltage (V) | Vcc | 0 | +3.6 | 
| Operating Relative Humidity (%) | RH | 0 | 85 | 
| Parameters | Symbol | Min. | Typical | Max. | |
| Supply Voltage (V) | Vcc | 3.15 | - | 3.45 | |
| Operating Case Temperature (°C) | Commercial | Tc | -5 | - | +70 | 
| Power Dissipation (W) | - | - | - | 1 | |
| Data Rate (Gbps) | - | - | 10.3125 | - | |
| Parameters | Symbol | Min. | Typical | Max. | |
| Transmitter Section | |||||
| Center Wavelength (nm) | lo | 1540 | 1550 | 1560 | |
| Spectral Width (RMS) (nm) | Dl | - | - | 1 | |
| Side-Mode Suppression Ratio | SMSR | 35 | - | - | |
| Average Output Power (dBm) | Po | 1 | - | 4 | |
| Extinction Ratio (dB) | Er | 3.5 | - | - | |
| Dispersion Penalty (dB) | - | - | 3.2 | ||
| Relative Intensity Noise (dB/Hz) | RIN12OMA | - | - | -128 | |
| Total Jitter (UI) | Tj | IEEE 802.3ae | |||
| Receiver Section | |||||
| Center Wavelength (nm) | lo | 1270 | 1610 | ||
| Receiver Sensitivity (dBm) | Rsen | - | - | -15 | |
| Stressed Sensitivity (dBm) | Rsen | - | - | -15 | |
| Receiver Overload (dBm) | Rov | -3 | - | - | |
| Return Loss (dB) | - | 12 | - | - | |
| LOS Assert (dBm) | LOSA | -20 | - | - | |
| LOS Dessert (dBm) | LOSD | - | - | -17 | |
| LOS Hysteresis (dBm) | - | 0.5 | - | 4 | |
| Parameters | Symbol | Min. | Typical | Max. | ||
| Transmitter Section | ||||||
| Input Differential Impendence (Ohm) | Zin | 90 | 100 | 110 | ||
| Data Input Swing Differential (mV) | Vin | 180 | - | 700 | ||
| TX Disable (V) | Disable | - | 2.0 | - | Vcc | |
| Enable | - | 0 | - | 0.8 | ||
| TX Fault (V) | Assert | - | 2.0 | - | Vcc | |
| Deassert | - | 0 | - | 0.8 | ||
| Receiver Section | ||||||
| Output Differential Impendence (Ohm) | Zout | 100 | - | |||
| Data Input Swing Differential (mV) | Vout | 300 | - | 800 | ||
| Rx_LOS (V) | Assert | - | 2.0 | - | Vcc | |
| Deassert | - | 0 | - | 0.8 | ||
| Address | Field Size (Bytes) | Name of Field | HEX | Description | 
| 0 | 1 | Identifier | 03 | SFP | 
| 1 | 1 | Ext. Identifier | 04 | MOD4 | 
| 2 | 1 | Connector | 07 | LC | 
| 3-10 | 8 | Transceiver | 10 00 00 00 00 00 00 00 | Transmitter Code | 
| 11 | 1 | Encoding | 06 | 64B66B | 
| 12 | 1 | BR, nominal | 67 | 10000Mbps | 
| 13 | 1 | Reserved | 00 | - | 
| 14 | 1 | Length (9um)-km | 0A | |
| 15 | 1 | Length (9um) | 64 | - | 
| 16 | 1 | Length (50um) | 00 | - | 
| 17 | 1 | Length (62.5um) | 00 | - | 
| 18 | 1 | Length (copper) | 00 | - | 
| 19 | 1 | Reserved | 00 | - | 
| 20-35 | 16 | Vendor name | 57 49 4E 54 4F 50 20 20 20 20 20 20 20 20 20 20 | WINTOP | 
| 36 | 1 | Reserved | 00 | - | 
| 37-39 | 3 | Vendor OUI | 00 00 00 | - | 
| 40-55 | 16 | Vendor PN | xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx | ASC II | 
| 56-59 | 4 | Vendor rev | 31 2E 30 20 | V1.0 | 
| 60-61 | 2 | Wavelength | 05 322 | 1550nm | 
| 62 | 1 | Reserved | 00 | - | 
| 63 | 1 | CC BASE | XX | Check sum of byte 0~62 | 
| 64-65 | 2 | Options | 00 1A | LOS, TX_DISABLE, TX_FAULT | 
| 66 | 1 | BR, max | 00 | |
| 67 | 1 | BR, min | 00 | |
| 68-83 | 16 | Vendor SN | 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 | Unspecified | 
| 84-91 | 8 | Vendor date code | XX XX XX 20 | Year, Month, Day | 
| 92-94 | 3 | Reserved | 00 | - | 
| 95 | 1 | CC_EXT | XX | Check sum of byte 64~94 | 
| 96-255 | 160 | Vendor specific | - | - | 


 
                SUN-GE9100B-VS 光线路终端(OLT)
型号:SUN-GE9100B-VS
1U机架提供2/4/8/16个PON口,最大可提供1024路(1:64分路比情况下)ONU接入
Features
 1U设备占用空间小,安装维护方便
 1U设备占用空间小,安装维护方便 最大提供16个下联EPON口、8个千兆上联光口和8个千兆上联网口
 最大提供16个下联EPON口、8个千兆上联光口和8个千兆上联网口 
                SUN-DC240 FTTH室内光缆
型号:SUN-DC240
FTTH室内光缆(GJXH),蝶型,钢丝/FRP/KFRP加强件,不带钢丝自承,LSZH外被
 
                SUN-OT5000 光时域反射仪OTDR
型号:SUN-OT5000
OTDR,单模/多模,各种动态范围,FC接口,SC/ST接口可选
Features
 开机启动时间短
 开机启动时间短 FTTx在线测试(可穿通1:64分路器)
 FTTx在线测试(可穿通1:64分路器) 内置PON光功率计(用于三网测试)(只限“-PON”型号)
 内置PON光功率计(用于三网测试)(只限“-PON”型号) 高配版配有稳定光源(LS)、普通光功率计(PM)、可视故障定位仪(VFL)和光纤端面检测仪(MCI)模块
 高配版配有稳定光源(LS)、普通光功率计(PM)、可视故障定位仪(VFL)和光纤端面检测仪(MCI)模块 USB数据接口(可利用上位机软件处理数据和输出报告)
 USB数据接口(可利用上位机软件处理数据和输出报告) 防尘、防震设计(通过2米跌落试验)
 防尘、防震设计(通过2米跌落试验) 重量轻、体积小、操作简单、坚固耐用
 重量轻、体积小、操作简单、坚固耐用 形象直观link image软件(选配)
 形象直观link image软件(选配) 
                SUN-ODB-RM2C 光缆终端箱
型号:SUN-ODB-RM2C
19英寸机架式,抽拉式,12/24/48/96芯,SC/方形FC/DLC/ST面板
 
                SUN-OPM200 光功率计
型号:SUN-OPM200
手持式光功率计,配合LS200光源使用,最大可提供6个波长的测试
Features
 用户自校准功能
 用户自校准功能 线性(mW)和非线性(dBm)指标同时显示
 线性(mW)和非线性(dBm)指标同时显示 10分钟无操作自动关机功能
 10分钟无操作自动关机功能 标配FC/SC/ST可替换接口
 标配FC/SC/ST可替换接口 背光显示
 背光显示 REF定义(参考光功率记录)功能
 REF定义(参考光功率记录)功能 背光智能控制
 背光智能控制 波长和频率自动识别
 波长和频率自动识别 大容量储存空间,数据存储可达1000条
 大容量储存空间,数据存储可达1000条 USB传输功能,方便数据储存入电脑
 USB传输功能,方便数据储存入电脑 
                SUN-OC-SLT-SP GYTS光缆
型号:SUN-OC-SLT-SP
GYTS室外光缆,束管层绞,金属加强芯,单钢铠单PE护套
Features
 具有良好的机械性能和温度特性
 具有良好的机械性能和温度特性 松套管材料具有良好的耐水解性能和较高的强度
 松套管材料具有良好的耐水解性能和较高的强度 良好的抗压性和柔软性
 良好的抗压性和柔软性 钢丝中心加强芯保证光缆的抗拉强度
 钢丝中心加强芯保证光缆的抗拉强度 涂塑钢带(PSP)提高光缆的抗透潮能力
 涂塑钢带(PSP)提高光缆的抗透潮能力